| General specifications | 
		
			| Switching function | Normally open (NO) | 
		
			| Output type | PNP | 
		
			| Rated operating distance | 20 mm | 
		
			| Installation | flush | 
		
			| Output polarity | DC | 
		
			| Assured operating distance | 0 ... 16.2 mm | 
		
			| Actual operating distance | 18 ... 22 mm typ. 20 mm | 
		
			| Reduction factor rAl | 0.33 | 
		
			| Reduction factor rCu | 0.31 | 
		
			| Reduction factor r304 | 0.74 | 
		
			| Reduction factor rBrass | 0.41 | 
		
			| Output type | 3-wire | 
		
			| Nominal ratings | 
		
			| Operating voltage | 10 ... 30 V DC | 
		
			| Switching frequency | 0 ... 440 Hz | 
		
			| Hysteresis | typ. 5 % | 
		
			| Reverse polarity protection | reverse polarity protected | 
		
			| Short-circuit protection | pulsing | 
		
			| Voltage drop | ≤ 2 V | 
		
			| Voltage drop at IL |  | 
		
			|  | Voltage drop IL = 1 mA, switching element on | 0.5 ... 2.3 V typ. 0.9 V | 
		
			|  | Voltage drop IL = 10 mA, switching element on | 0.8 ... 2.2 V typ. 1.4 V | 
		
			|  | Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.3 V typ. 1.5 V | 
		
			|  | Voltage drop IL = 50 mA, switching element on | 0.9 ... 2.5 V typ. 1.6 V | 
		
			|  | Voltage drop IL = 100 mA, switching element on | 1 ... 2.6 V typ. 1.8 V | 
		
			|  | Voltage drop IL = 200 mA, switching element on | 1.2 ... 2.8 V typ. 2 V | 
		
			| Operating current | 0 ... 200 mA | 
		
			| Off-state current | 0 ... 0.5 mA typ. 0.01 mA | 
		
			|  | Off-state current TU =40 °C, switching element off | ≤ 100 µA | 
		
			| No-load supply current | ≤ 10 mA | 
		
			| Time delay before availability | ≤ 50 ms | 
		
			| Operating voltage indicator | LED, green | 
		
			| Switching state indicator | LED, yellow | 
		
			| Functional safety related parameters | 
		
			| MTTFd | 1289 a | 
		
			| Mission Time (TM) | 20 a | 
		
			| Diagnostic Coverage (DC) | 0 % | 
		
			| Compliance with standards and directives | 
		
			| Standard conformity |  | 
		
			|  | Standards | EN IEC 60947-5-2 | 
		
			| Approvals and certificates | 
		
			| UL approval | cULus Listed, General Purpose | 
		
			| CCC approval | CCC approval / marking not required for products rated ≤36 V | 
		
			| Ambient conditions | 
		
			| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | 
		
			| Mechanical specifications | 
		
			| Connection type | screw terminals | 
		
			| Core cross section | max. 2.5 mm2 | 
		
			| Housing material | PA/metal with epoxy powder coating | 
		
			| Sensing face | PA | 
		
			| Housing base | metal | 
		
			| Degree of protection | IP68 / IP69K | 
		
			| Mass | 225 g | 
		
			| Dimensions |  | 
		
			|  | Height | 40 mm | 
		
			|  | Width | 40 mm | 
		
			|  | Length | 118 mm | 
		
			| Note | Tightening torque: 1.8 Nm (housing) |